• OB视讯官网

    NEBNext Ultra II Ligation Module (NEB # E7595) for NEBNext Ultra II FS DNA Module (NEB # E7810)

    New England Biolabs, Juliet Bonnevie

    Published: 2023-06-16 DOI: 10.17504/protocols.io.n92ld3xw9g5b/v2
    AI 解读
    浏览 1333

    Abstract

    This module is part of the Ultra™ II workflow, and is optimized for use with the NEBNext®Ultra II End Repair/dA-Tailing Module (NEB #E7546), for Illumina®-compatible library construction.

    The NEBNext Ultra II Ligation Module is optimized for use with the NEBNext Ultra II End Repair/dA-Tailing Module (NEB #E7546) or the NEBNext Ultra II FS DNA Module (NEB #E7810).

    Before start

    Starting Material: 100 pg–500 ng fragmented, end repaired and dA-Tailed DNA generated using the NEBNext Ultra II FS DNA Module (NEB #E7810)

    Note
    Caution: If DNA input is < 100 ng, dilute the (red) NEBNext Adaptor for Illumina in 10 mM Tris-HCl, pH 7.5-8.0 with 10 mM NaCl as indicated in Table 2.1.

    Steps

    DNA Ligation/End Prep

    1.

    Add the following components directly to the FS Reaction Mixture:

    AB
    ComponentVolume
    FS Reaction Mixture35 µl
    (red) NEBNext Adaptor for Illumina**2.5 µl
    (red) NEBNext Ultra II Ligation Master Mix*30 µl
    (red) NEBNext Ligation Enhancer1 µl
    Total volume68.5 µl
    • Mix the Ultra II Ligation Master Mix by pipetting up and down several times prior to adding to the reaction.

    ** The NEBNext adaptor is provided in NEBNext Oligo kit options, which can be found at www.neb.com/oligos

    Note
    Note: The Ligation Master Mix and Ligation Enhancer can be mixed ahead of time and is stable for at least 8 hours @ 4°C. We do not recommend premixing the Ligation Master Mix, Ligation Enhancer and adaptor prior to use in the Adaptor Ligation Step.

    2.

    Set a 100 µl or 200 µl pipette to 50 µl and then pipette the entire volume up and down at least 10 times to mix thoroughly. Perform a quick spin to collect all liquid from the sides of the tube.

    Note
    Caution: The NEBNext Ultra II Ligation Master Mix is very viscous. Care should be taken to ensure adequate mixing of the ligation reaction, as incomplete mixing will result in reduced ligation efficiency. The presence of a small amount of bubbles will not interfere with performance.

    3.

    Incubate at 20°C for 0h 15m 0s in a thermocycler with the heated lid off .

    4.

    Add 3 µl of (red) USER Enzyme to the ligation mixture.

    Note
    Note: Steps 4 and 5 are only required for use with NEBNext Adaptors. USER enzyme can be found in most NEBNext oligo kits, all options can be found on the Note: Steps 4 and 5 are only required for use with NEBNext Adaptors. USER enzyme can be found in most NEBNext oligo kits, all options can be found on the www.neb.com/oligos page. If you are using the indexed UMI adaptor, USER is not needed. Please see corresponding manual for use with UMI on the E7395 product page under protocols, manuals, and usage tab. page. If you are using the indexed UMI adaptor, USER is not needed. Please see corresponding manual for use with UMI on the E7395 product page under protocols, manuals, and usage tab.

    5.

    Mix well and incubate at 37°C for 0h 15m 0s with the heated lid set to ≥ 47°C.

    6.

    DNA is now ready for size selection or cleanup.

    Note
    Note: Please see NEB #E7805/#E6177 manual for recommended size selection/cleanup and PCR amplification protocols.

    Note
    Safe Stop Point: Samples can be stored overnight at –20°C.